Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics

Product Details
Customization: Available
Material: Powder
Feature: Light Proof Bottle Design
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
R&D Capabilities
The supplier has 19 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (28)
  • Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
  • Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
  • Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
  • Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
  • Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
  • Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Packing & Delivery
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
022041
Transport Package
Carton
Specification
250g/bottle
Trademark
HKM
Origin
Guangdong, China
HS Code
3821000000

Product Description

Product Description
HKM Company has been in Microbial Detection since 1993, with manufacture base over 20,000 sq.m ,1200 sq.m of Microbiological Research Lab and GMP room and 300 staffs,HKM has a full range of Culture Media as below :
Dehydrated Culture Media
Granular Media
Chromegenic Media
Ready-to-use Culture Media
Triple wrapped contact plate & settle plate
Media Raw Materia
Other Microbial Detection Products
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
Specification
Item
Value
Form
Powder
Packaging
Bottle, Drum
Place of Origin
China, Guangdong 
Brand Name
HKM CHINA
Model Number
022041
Physical behavior
Powder
Color
light yellow
Packing & Delivery
Package:250g/ bottle :Packed in plastic bottles with plastic film wrapped, 20 bottles / carton.
Carton size :57*33*17cm
Other packing also available according to customers demand.
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.
Company Profile
 
Guangdong HuanKai Microbial Sci. & Tech. Co.,Ltd. is a national high-tech enterprise under the Guangdong Institute of Microbiology which is attached to Guangdong Academy of Sciences. Since established in 1993, HuanKai has adhered to the strategy of scientific and technological innovation and development, and has formed four product lines including microbiological testing reagents and consumables, digital laboratory instruments, physical and chemical rapid water detecting products, and high-efficiency environmentally friendly cleaning agents and disinfectant, both are with independent intellectual property rights. More than 2, 000 varieties of products are widely applied in mainland China, Hong Kong, Macao, Taiwan and Southeast Asia. Huankai has developed into an important R&D production base for domestic food and other industry.
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
Lactose Bile Broth Salt Medium Without Neutralizers Dry Powder for Enumeration of Fecal Coliforms in Cosmetics
FAQ
Q1:Sometimes color of dehydrated culture media between batches have subtle differences,would this affect test results?
The source and storage conditions of raw material is different ,so there may be a slight difference in color, which is a normal phenomenon. Products from our company have to undergo a rigorous inspection and sensory biology verification before sale, to ensure that all the indicators characteristics of the product is under enterprise standard to the extent permitted, not affect the test results.

Q2: After pouring the liquid medium on the plate , medium seems hard to clot or coagulation time is longer, is it some problem with product quality?
The reason may be: The required hydration in the preparation process have not been done completely .That is to say distilled water is not boil sufficiently to dissolve agar. Because agar proportion, easily settle in the bottom of the bottle, if not fully shaken after
high-temperature sterilization, it will lead to uneven upper agar culture gene content and difficult to set.

Q3: Why some colonies of E. coli chromogenic medium color not shown above, but also confirmed through biochemical tests for E. coli (false negative)?
E. CHROMOGENIC medium is based on the principle of specific enzyme of E. coli and design, 94% of E. coli have β-glucuronidase enzyme, with the chromogenic enzyme substrate medium role in the formation of blue-green colonies. And about 4% of the E. coli does not have β- glucuronidase enzymes, including concern O157: H7 Escherichia coli. Therefore, these E. coli can not be displayed on the color characteristic of E. coli chromogenic medium,it is possible of false-negative on the chromogenic medium. However, the traditional medium of the same can not avoid the problem of false negatives, such as: no gas or slow ferment lactose intolerance may also strain 44.5 false negatives in the conventional medium. For this small part of the E. coli can be detected using other
methods.

Q4:During anaerobic or micro-aerobic culture, is it necessary to remove gas bag from package? How to use oxygen indicator?
During anaerobic or micro-aerobic culture, using method of gassing agent should be done according to the manufacturer's instructions. Remove the paper bag from the plastic packaging, but do not cut the paper bag. Torn the outer packaging of oxygen indicator then it can be used.
 
5. Who are we?
We are based in Guangdong, China, start from 1993,sell to Domestic Market(80.00%),Southeast Asia(5.00%),Mid East(5.00%),Africa(3.00%),South America(2.00%),North America(1.00%),Eastern Europe(1.00%),South Asia(1.00%),Central America(1.00%),Western Europe(1.00%). There are total about 301-500 people in our office.

6. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

7.What can you buy from us?
Microbial Detection Product,Peptone&Tryptone,Deydrated Culture Media,Granular Media,Microbial Air Sampler and so on.

8. Why should you buy from us not from other suppliers?
1.With strong R&D capacity and good scientific research conditions,over 30 years of experience 2.Largest culture media manufactuer in China follow international standard 3.Stable high quality main raw material from Europe & strictly quality control

9. What services can we provide?
Accepted Payment Currency:USD,EUR,CNY;
Accepted Payment Type: T/T,MoneyGram,PayPal,Western Union,Cash,Escrow;
Language Spoken:English,Chinese

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier