• Simon Citrate Identification Tube for Diagnostic of Microorganisms
  • Simon Citrate Identification Tube for Diagnostic of Microorganisms
  • Simon Citrate Identification Tube for Diagnostic of Microorganisms
  • Simon Citrate Identification Tube for Diagnostic of Microorganisms
  • Simon Citrate Identification Tube for Diagnostic of Microorganisms
  • Simon Citrate Identification Tube for Diagnostic of Microorganisms

Simon Citrate Identification Tube for Diagnostic of Microorganisms

CAS No.: Simon Citrate
Formula: Chemical Reagents
EINECS: Biochemical
Classification: Physicochemical Reagent
Specific Usage: Technical Grade, Physicochemical Analysis
Content: Standard
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Guangdong, China
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 10 R&D engineers, you can check the Audit Report for more information
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (24)

Basic Info.

Model NO.
075200
Usage
Laboratory Reagents, Analytical Reagents, Teaching Reagents
Source
Physicochemical Reagent
Habit Appellation
Physicochemical Reagent
Application
Industry, Scientific Research
Property
Physicochemical Reagent
Transport Package
N/a
Specification
20 vials/box
Trademark
HKM
Origin
China
Production Capacity
5000 Boxes/Week

Product Description

 

 

 

Product Description

 

Usages:

 

For biochemical identification of microorganisms.

 

Instructions of biochemical identification tube

1. Opening of vial

Before opening the vials, surface disinfection with 75% alcohol cotton . Then open the plastic cover with direction of the arrow , and then open aluminum cover under sterile conditions .

2. Using of biochemical identification tube

Colonies were picked to be tested with Gram staining, fresh colony was inoculated  in ordinary broth and culture at 37 for 18-24h or diluted with 0.85% sterile saline to 0.5McFa-rland (about 108cfu / mL), draw 0.05-0.08mL (about 1 to 2 drops) of broth or bacterial suspension,and added into micro-resistant bottle. Then put the rubber plug, generally using full-stopper (shown in Figure 2 bottles left), special circumstances in the following table indicate the semi-stoppered (shown in Figure 2 the right two bottles), put the vial in the Neto groove (Figure 2), or place in a suitable bottle holder and incubated at 35-37 .

The results observed in Table 1 below.

 

Note: For special vaccination way, incubation time or training methods, please refer to instructions included with each biochemical identification tube.

 

Simon Citrate Identification Tube for Diagnostic of Microorganisms

 

Code

Name

Code

Name

 

075050

Sucrose biochemical identification tube

075370

Glucose gas

075040

Mannitol biochemical identification tube

075610

Acetamide

075030

Maltose biochemical identification tube

075600

Arginine double hydrolase control

075020

Lactose biochemical identification tube

075590

Arginine double hydrolase

075010

Glucose biochemical identification tube

075580

Arginine decarboxylase

075150

Urea biochemical identification tube

075570

Cellobiose

075130

Adonis Aging identification tube

075560

Melibiose

075140

Salicin biochemical identification tube

075550

Fructose

075120

Inositol biochemical identification tube

075540

Inulin

075110

Rhamnose biochemical identification tube

075530

Mushroom sugar

075100

Dulcitol biochemical identification tube

075522

Mucate QC broth

075090

Sorbitol biochemical identification tube

075720

Meilan milk 0.1%

075080

Galactose biochemical identification tube

075700

40% of the bile broth

075070

Xylose biochemical identification tube

075630

PH9.6 broth

075060

Arabinose biochemical tube

075680

6.5% high-salt broth

075260

Glucose ammonium biochemical identification tube

075670

UIM(Urea Indole Motility Medium)

075250

Glucose phosphate broth biochemical identification tube

075660

SIM ( Sulfide Indole Motility Medium)

075240

Peptone water broth biochemical identification tube

075650

Purple milk

075230

Raffinose biochemical identification tube

075640

OF (Hugh-leifson)

075220

Phenylalanine biochemical identification tube

075630

Nitrite (gas)

075210

Gluconate biochemical identification tube

075620

Nitrate (gas)

075200

Simon's citrate biochemical identification tube

075850

Lactose gelatin

075190

Malonate biochemical identification tube

075840

Glycerol fermentation tube

075180

B- galactosidase, ONPG biochemical identification tube

075810

Buffer power - nitrate

075160

Esculin biochemical identification tube

075800

Acetamide broth

075360

5% lactose

075780

Koser's citrate broth

075350

Semisolid agar

075770

Hippurate

075260

Potassium cyanide control tube (KCN) biochemical identification tube

075760

Glucose semisolid

075330

Potassium cyanide biochemical identification tube

075750

Triple sugar iron

075260

Nitrate (reducing) biochemical identification tube

075740

Bile lysis control

075310

Gelatin biochemical identification tube

075730

Bile bacteriolysis

075300

Hydrogen sulfide biochemical identification tube

075510

DNA

075290

Amino acid decarboxylase control biochemical identification tube

075490

Acetate

075280

Lysine decarboxylase biochemical identification tube

075480

Starch

075270

Ornithine decarboxylase biochemical identification tube

075440

Sorbitol

075521

Mucate test broth

075430

Melizitose

075420

Turanose

075400

D- ribose

075380

Mannose

 

 


Packaging & Shipping

Packing material: Packed in westwood vials with plastic bottom
Capacity: 20 pcs / unit

Our Services
1.Offering Free Sample for Testing .
2.R & D team to provide technical support.
3.Provide packaging, labeling OEM customization.

FAQ
Q1:Sometimes color of dehydrated culture media  between batches have subtle differences,would this affect test results?

A1:The source and storage conditions of raw material is different ,so there may be a slight difference in color, which is a normal phenomenon. Products from our company have to undergo a rigorous inspection and sensory biology verification before sale, to ensure that all the indicators characteristics of the product is under enterprise standard to the extent permitted, not affect the test results.

 

Q2:After pouring the liquid medium on the plate , medium seems hard to clot or coagulation time is longer, is it some problem with product quality?

A2: The reason may be:

The required hydration in the preparation process have not been done completely .That is to say   distilled water is not boil sufficiently to dissolve agar. Because agar proportion, easily settle in the bottom of the bottle, if not fully shaken after high-temperature sterilization, it will lead to uneven upper agar culture gene content and difficult to set.

 

Q3:Why some colonies of E. coli chromogenic medium color not shown above, but also confirmed through biochemical tests for E. coli (false negative)?

A3: E. CHROMOGENIC medium is based on the principle of specific enzyme of E. coli and design, 94% of E. coli have β- glucuronidase enzyme, with the chromogenic enzyme substrate medium role in the formation of blue-green colonies. And about 4% of the E. coli does not have β- glucuronidase enzymes, including concern O157: H7 Escherichia coli. Therefore, these E. coli can not be displayed on the color characteristic of E. coli chromogenic medium,it is possible of false-negative on the chromogenic medium. However, the traditional medium of the same can not avoid the problem of false negatives, such as: no gas or slow ferment lactose intolerance may also strain 44.5 false negatives in the conventional medium. For this small part of the E. coli can be detected using other methods.

 

Q4:During anaerobic or micro-aerobic culture, is it necessary to remove gas bag from package? How to use oxygen indicator?

A4: During anaerobic or micro-aerobic culture, using method of gassing agent should be done according to the manufacturer's instructions. Remove the paper bag from the plastic packaging, but do not cut the paper bag. Torn the outer packaging of oxygen indicator then it can be used.

Company Information

 

Simon Citrate Identification Tube for Diagnostic of Microorganisms Simon Citrate Identification Tube for Diagnostic of MicroorganismsSimon Citrate Identification Tube for Diagnostic of Microorganisms

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now